GAP T degradation

LightningSimulate Model on JWS BuildDownload ZoomView content

An exponential decay model was fitted to the experimental data set of GAP degradation at 70C. The model is uploaded as an SBML file. A data file showing the model fit to the experimental data set is included. The rate constant for GAP degradation at 70C was estimated to be 0.056 1/min, equivalent to a half life time of 12.4 min.

SEEK DEMO ID: http://demo.seek4science.org/models/22?version=1

1 item is associated with this Model:
  • GAPdeg.xml (XML document - 1.28 KB) Zoom Download

Organism: Not specified

Model type: Ordinary differential equations (ODE)

Model format: SBML

Execution or visualisation environment: JWS Online

Model image: No image specified

help Contributor and Creators
License
No license specified
Activity

Views: 748   Downloads: 72

Created: 29th Jan 2013 at 22:24

Last updated: 28th May 2015 at 10:50

Last used: 19th Sep 2017 at 13:40

help Attributions

None

help Scales
Not Specified